Southwire 4 AWG Stranded Copper THHN/THWN-2 Building Wire, White — 500 ft

$1,120.00Add to cart for lowest price

4 AWG stranded copper THHN/THWN-2, white, 500 ft. 85 A at 75°C — generator feeder wire to about 17 kW.

Southwire 4 AWG stranded copper THHN/THWN-2 in white, 500 ft. Single conductor, 600 volt, rated 90°C wet or dry — so it is legal in conduit outdoors and underground, where plain THHN is not.

This Is Generator Feeder Wire

Between a standby generator and its transfer switch, NEC 445.13 requires conductors rated at not less than 115% of the generator nameplate current — a different and larger figure than the ordinary ampacity table gives you.

At 85 amps (75°C), 4 AWG covers a generator up to roughly 17 kW at 240 volts on that basis.

60°C column 70 A
75°C column — the usual working limit 85 A
90°C column 95 A
Suits generators to about 17 kW at 240 V (NEC 445.13)

NEC 110.14(C) pulls the circuit back to the lowest-rated termination, and lugs in ordinary gear are listed at 75°C — so the middle figure is your number. The 90°C rating is what you derate from when conduit fill or ambient heat apply.

A Typical Standby Feeder

A generator feeder is not one wire. For a mid-range air-cooled set an installer will commonly pull:

  • Two hots — black and red
  • One neutral — white, often a size smaller than the hots
  • One equipment ground — green, smaller again, sized to NEC 250.122
  • Control conductors between the generator and the transfer switch, per the manufacturer’s harness

Tell us the generator model and the run length and we will work out the whole pull for you — it is quicker than guessing and cheaper than a second trip.

Wet Locations and the THWN-2 Rating

The inside of a conduit run outdoors or underground is a wet location under NEC 300.5(B) and 300.9, no matter how well sealed. Plain THHN is dry-rated only. This wire is dual-rated THHN/THWN-2, which is what a generator feeder in buried conduit requires.

Run Length Matters

Ampacity is the first test; voltage drop is the second. Past roughly 100 feet on a loaded feeder you should be checking drop, and it frequently forces a size up. See wire size for a 100 foot run and what size wire between a generator and transfer switch.

What White Means

In white, this conductor is the grounded conductor — the neutral.

Specifications

Brand Southwire
Type THHN / THWN-2 single conductor building wire
Size 4 AWG
Conductor Stranded annealed copper
Insulation PVC with nylon jacket
Color White
Voltage rating 600 V
Temperature rating 90°C dry, 90°C wet (THWN-2)
Ampacity at 75°C 85 A
Length 500 ft
Approx. shipping weight 84 lb
Approvals UL 83, UL 1063

Why Buy Wire From ZapDaddy Supplies

  • Licensed electricians answer the phone — we will size the feeder with you before you order
  • Generator, switchgear and wire in one order, so the job ships together
  • Straight answers on code — 445.13, 250.122 and voltage drop, worked out for your actual run

Ready to Order?

Add it to the cart to see your price. Copper moves daily and our cart price tracks it.

Attributes Value
Brand

Wire Gauge

Conductor

Copper

Length

500 ft

Reviews

Be the first to review “Southwire 4 AWG Stranded Copper THHN/THWN-2 Building Wire, White — 500 ft”

Your email address will not be published. Required fields are marked *

Southwire 4 AWG Stranded Copper THHN/THWN-2…$1,120.00Add to cart