Licensed electrical contractor — we install the equipment we sell

832-257-1977 ·  david@zapdaddyelectric.com

Licensed electricians, not a call center

Free freight on standby generators

Generator, switch and wire in one order

Specs checked against the manufacturer

Nearly every generator sizing guide gives you a rule of thumb — “18kW runs most homes” — and leaves you to guess. This one does the arithmetic, and it does the one thing the others miss: it sizes against the fuel you are actually going to run.

Generator Sizing Calculator

Sized against the fuel you will actually run — which is the step almost every other calculator skips.

Most homes are on gas, and most units produce less on it.
Add the tonnage of every system together.
Conditioned living area.

Why the fuel you run changes the answer

A dual fuel standby generator has two output ratings, and the number on the box is the propane one. On natural gas most units produce less, because gas carries less energy per cubic foot.

That gap is not trivial, and it is not consistent between brands:

ModelOn propaneOn natural gasLoss
Briggs & Stratton 22kW22 kW22 kWnone
Generac 22kW (7260)22 kW21 kW4.5%
Kohler 20RCA20 kW18 kW10%
Kohler 14RCA14 kW12 kW14.3%
Generac 28kW (7282)28 kW25 kW10.7%
Manufacturer published ratings. The calculator above uses these figures for all 43 standby models we stock.

So a “22kW” is not a 22kW if you are on gas — unless it is the Briggs. If you size from the badge and run on natural gas, you can end up a size short without ever doing anything wrong.

Running load is not the whole story

Two numbers decide generator size. The running load is everything drawing power at once. The starting surge is the extra current a motor pulls for a second or two when it kicks in — and for most homes that is the air conditioner compressor, which can momentarily draw two to three times its running figure.

That surge is usually what decides the size, and it is why a generator can look big enough on a spreadsheet and still stall when the AC starts. The calculator shows both numbers so you can see which one is driving your answer.

Whole house or essential circuits?

Whole house means the generator carries the entire panel and you notice nothing except the ten-second pause while it starts. It is the right answer if outages at your place are long, or if you are not home when they happen.

Essential circuits means you pick what matters — heat, water, refrigeration, a few outlets — and leave the rest dark. It is dramatically cheaper, because the generator, the switchgear and often the gas supply all get smaller. For many houses it is the sensible choice, and nobody selling generators will tell you that.

There is a middle road too: a load management module lets a smaller generator cover a bigger house by shedding the air conditioning for a minute when capacity gets tight. It frequently pays for itself at the point of purchase.

What this calculator is, and is not

It is a planning estimate built on the NEC 220.82 optional method for a one-family dwelling, with a 10% headroom allowance, filtered against published per-fuel ratings. It will get you to the right size bracket and the right shortlist.

It is not a load calculation for a permit, and it cannot see your panel. Service size, existing loads, gas meter capacity and run distance all affect the final answer. Before you spend several thousand dollars, send us the numbers — a licensed electrician will check them against your actual installation, free, and tell you if you can go smaller.

What else you will need

A generator is one line on the job. You will also need a transfer switch — sized to your electrical service, not to the generator — and conductors between the two, sized under NEC 445.13 at 115% of nameplate current rather than the ordinary ampacity table. Our guide on what size wire you need covers that.

Ask us and we will quote the whole job — generator, switch and wire — so nothing turns up missing on install day.