Licensed electrical contractor — we install the equipment we sell

832-257-1977 ·  david@zapdaddyelectric.com

Licensed electricians, not a call center

Free freight on standby generators

Generator, switch and wire in one order

Specs checked against the manufacturer

Generac RTSW300A3 300-Amp GenReady Automatic Transfer Switch

$3,485.00Add to cart for lowest price

300A smart automatic transfer switch with load management — lets a smaller generator cover a bigger house.

Generac 300A smart automatic transfer switch. GenReady switch with built-in load management for a 300 amp service. Beyond transferring the load, it actively manages which circuits run when generator capacity gets tight.

Why You Cannot Skip the Transfer Switch

A transfer switch is not an accessory. It is the device that makes generator power legal and safe, and it does one essential thing: it guarantees your house is never connected to the generator and the utility at the same time.

Without it, generator power flows backwards out of your house and onto the utility line. That line is being worked on by someone who has confirmed it is dead. Your generator re-energises it, and the step-up through the pole transformer turns 240 volts into several thousand. Backfeeding kills linemen. It is also illegal everywhere in the United States, it will fail inspection, and it voids your homeowner’s insurance.

NEC 702.5 requires the transfer equipment. There is no version of this job that skips it.

Load Management: Why This Costs More and Saves More

Sizing a generator to run everything at once is expensive, and almost always unnecessary — because in a real house everything is not on at once. A smart switch enforces that.

It watches generator output and sheds the heavy loads when capacity runs short, bringing them back as headroom returns. Air conditioning is the usual target: the largest intermittent load in most houses, and the one nobody minds waiting two minutes for.

The effect is that a smaller generator covers a house that would otherwise need a much larger one. The saving is typically thousands of dollars, and it comes out of the generator, the pad, the gas supply and the switchgear together. A smart switch frequently pays for itself at the point of purchase, not over time.

The trade: under peak demand something gets shed briefly. If you have a medical requirement or equipment that genuinely cannot be interrupted, size the generator properly rather than relying on shedding.

Service-Rated or Not? This Is the Decision

More orders go wrong on this point than on amperage, so it is worth being precise.

Service-entrance rated Contains a main breaker and can act as the service disconnect. It replaces your main, sitting between the meter and the panel. Fewer boxes on the wall, usually less conduit, and often a cleaner install on a retrofit.
Not service-rated No main disconnect inside. It must be installed downstream of an existing main. Cheaper, and the right answer when you already have a perfectly good service disconnect you are keeping.

Which you need depends on your existing service, not on preference. If your meter feeds a main breaker panel and that panel is staying, a non-service-rated switch downstream is usually correct. If you are replacing the service equipment, or the meter feeds the panel directly with no separate disconnect, you need the service-rated version.

Your inspector will check this. Send us a photo of your meter and panel and we will tell you which one you need before you buy the wrong box.

Size It to the Service, Not the Generator

The amperage on a transfer switch matches your electrical service, not your generator’s output. A 200 amp service takes a 200 amp switch, whether the generator behind it is 14kW or 26kW.

Look at the main breaker in your panel. That number — 100, 150, 200, 400 — is the number you need. Getting this wrong in either direction is a problem: undersized is a code violation and a hazard, oversized is money spent for nothing.

You will also need conductors between the generator and the switch, and that sizing has its own rule — NEC 445.13 requires 115% of nameplate current, which is not the figure in the ordinary ampacity table. Read what size wire you need before the trench is open, and see our THHN/THWN-2 building wire.

Specifications

Manufacturer part RTSW300A3
Brand Generac
Rating 300A
Voltage 120/240 V single phase
Type Automatic transfer switch
Service-entrance rated Confirm for your configuration
Installed by Licensed electrician — permit and inspection required in most jurisdictions
Genuine OEM Yes

Compatibility depends on your generator’s controller generation. Tell us your generator model and we will confirm the pairing.

Why Buy From ZapDaddy Supplies

  • Licensed electricians answer the phone — send us a photo of your panel and we will confirm the switch before you order
  • Generator, switch and wire ship together so the installer has the whole job on site
  • Straight answers on code — we will tell you what your inspector is going to ask

Ready to Order?

Add it to the cart to see your price. If you are at all unsure whether you need the service-rated version, call first — it is a far cheaper conversation than a returned switch.

Attributes Value
Brand

Amperage

300A

Voltage

120/240V

Phase

Single Phase

Complete the job

Compare similar models

Reviews

Be the first to review “Generac RTSW300A3 300-Amp GenReady Automatic Transfer Switch”

Your email address will not be published. Required fields are marked *

Generac RTSW300A3 300-Amp GenReady Automatic Transfer…$3,485.00Add to cart