Kohler RXT-JFNC-200ASEQS5 200-Amp Service-Entrance Rated Automatic Transfer Switch

$1,055.00Add to cart for lowest price

200A service-entrance rated automatic transfer switch — includes a main disconnect.

Kohler 200A service-entrance rated automatic transfer switch. Service-entrance rated, NEMA 3R aluminum enclosure, single phase 2-pole, with load-shed board and auxiliary breaker. It watches the utility feed, starts the generator when power fails, transfers the load, and hands it back when the grid returns — with nobody home.

Why You Cannot Skip the Transfer Switch

A transfer switch is not an accessory. It is the device that makes generator power legal and safe, and it does one essential thing: it guarantees your house is never connected to the generator and the utility at the same time.

Without it, generator power flows backwards out of your house and onto the utility line. That line is being worked on by someone who has confirmed it is dead. Your generator re-energises it, and the step-up through the pole transformer turns 240 volts into several thousand. Backfeeding kills linemen. It is also illegal everywhere in the United States, it will fail inspection, and it voids your homeowner’s insurance.

NEC 702.5 requires the transfer equipment. There is no version of this job that skips it.

Service-Rated or Not? This Is the Decision

More orders go wrong on this point than on amperage, so it is worth being precise.

Service-entrance rated Contains a main breaker and can act as the service disconnect. It replaces your main, sitting between the meter and the panel. Fewer boxes on the wall, usually less conduit, and often a cleaner install on a retrofit.
Not service-rated No main disconnect inside. It must be installed downstream of an existing main. Cheaper, and the right answer when you already have a perfectly good service disconnect you are keeping.

Which you need depends on your existing service, not on preference. If your meter feeds a main breaker panel and that panel is staying, a non-service-rated switch downstream is usually correct. If you are replacing the service equipment, or the meter feeds the panel directly with no separate disconnect, you need the service-rated version.

Your inspector will check this. Send us a photo of your meter and panel and we will tell you which one you need before you buy the wrong box.

This unit is the service-rated version — it contains a main disconnect and can serve as your service equipment.

Size It to the Service, Not the Generator

The amperage on a transfer switch matches your electrical service, not your generator’s output. A 200 amp service takes a 200 amp switch, whether the generator behind it is 14kW or 26kW.

Look at the main breaker in your panel. That number — 100, 150, 200, 400 — is the number you need. Getting this wrong in either direction is a problem: undersized is a code violation and a hazard, oversized is money spent for nothing.

What Automatic Actually Buys You

A manual switch costs a fraction of this and does the same electrical job. The difference is that somebody has to be standing there to throw it.

Automatic matters when the outage happens while you are at work, asleep, or on holiday. It is the difference between a freezer that keeps running and one you find three days later, between a sump pump that keeps the basement dry and one that does not, between pipes that stay warm and pipes that burst. If the reason you are buying a generator is to protect the house when you are not in it, the switch has to be automatic.

You will also need conductors between the generator and the switch, and that sizing has its own rule — NEC 445.13 requires 115% of nameplate current, which is not the figure in the ordinary ampacity table. Read what size wire you need before the trench is open, and see our THHN/THWN-2 building wire.

Specifications

Manufacturer part RXT-JFNC-200ASEQS5
Brand Kohler
Rating 200A
Voltage 120/240 V single phase
Type Automatic transfer switch
Service-entrance rated Yes — includes a main disconnect
Installed by Licensed electrician — permit and inspection required in most jurisdictions
Genuine OEM Yes

Compatibility depends on your generator’s controller generation. Tell us your generator model and we will confirm the pairing.

Why Buy From ZapDaddy Supplies

  • Licensed electricians answer the phone — send us a photo of your panel and we will confirm the switch before you order
  • Generator, switch and wire ship together so the installer has the whole job on site
  • Straight answers on code — we will tell you what your inspector is going to ask

Ready to Order?

Add it to the cart to see your price. If you are at all unsure whether you need the service-rated version, call first — it is a far cheaper conversation than a returned switch.

Attributes Value
Brand

Amperage

200A

Voltage

120/240V

Phase

Single Phase

Complete the job

Compare similar models

Reviews

Be the first to review “Kohler RXT-JFNC-200ASEQS5 200-Amp Service-Entrance Rated Automatic Transfer Switch”

Your email address will not be published. Required fields are marked *

Kohler RXT-JFNC-200ASEQS5 200-Amp Service-Entrance Rated Automatic…$1,055.00Add to cart