All-electric homes are the hardest case in standby power, and most sizing advice quietly ignores them. The reason is simple: electric resistance heat is an enormous load and it runs for hours.
What makes it different
| Load | Gas home | All-electric home |
|---|---|---|
| Heating | ~600 W blower | 10,000–20,000 W |
| Water heating | 0 W | 4,500 W |
| Range / oven | 0 W | 8,000 W |
| Clothes dryer | ~600 W | 5,000 W |
| Difference | ~27 kW of added load |
Electric strip heat alone can exceed the output of every air-cooled standby generator made. A 20 kW heat kit is larger than a 26kW generator can carry while anything else runs.
Your three realistic options
1. Liquid-cooled, and size it properly
For genuine whole-house backup of an all-electric home, you are usually looking at 30 kW and up. Our liquid-cooled range starts at the Kohler 24RCLA at $16,800 and runs to 60 kW.
Worth knowing: the Kohler 30RCLA, 38RCLC and 48RCLC have no natural gas derate — 30 kW is 30 kW on either fuel. Every air-cooled unit loses capacity on gas, so that matters at this end of the range.
2. Heat pump instead of strip heat
If your heating is a heat pump rather than resistance elements, the picture improves enormously. A heat pump in heating mode draws roughly what it draws in cooling mode — a few kilowatts, not twenty.
The catch is auxiliary heat. Most heat pumps have electric strip backup that engages in very cold weather or during defrost, and that is the load that will trip you. Some systems can lock out auxiliary heat when on generator power. Ask your HVAC contractor whether yours can.
3. Decide heat is not on the generator
This is the honest option nobody offers. Back up refrigeration, lighting, outlets, water and the furnace blower — and accept that resistance heat stays off, using a gas fireplace or space heating in one room instead.
It is far cheaper, and it is what many all-electric homes actually do once they see the quote for the alternative.
Load management is close to mandatory here
With this many large loads, load management stops being an upgrade and becomes part of the design. Shedding the water heater, the range and the dryer during peak lets a far smaller generator cover the house.
A 100 amp load manager at $270 can save you the step from air-cooled to liquid-cooled — a difference of roughly $10,000.
Run the numbers before anything else
All-electric is where guessing gets expensive in both directions. Our sizing calculator has a dedicated input for electric strip heat because it changes the answer more than any other single item.
Square footage is a starting point, not an answer. Run the sizing calculator — it works from your actual loads and sizes against the fuel you run — or send us the details and a licensed electrician will check it.
Frequently Asked Questions
What size generator for an all-electric house?
Usually 30 kW or more for genuine whole-house backup, which means a liquid-cooled unit. Electric strip heat alone can exceed the output of any air-cooled standby generator.
Can a 26kW generator run an all-electric home?
Not with electric resistance heat running. It can carry an all-electric home with load management and the heat shed, or one heated by a heat pump with auxiliary heat locked out.
Is a heat pump better for generator backup?
Much better. A heat pump draws a few kilowatts rather than the 10 to 20 kW of resistance heat. The problem is the auxiliary strip heat that engages in cold weather — ask whether yours can be locked out on generator power.